Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge
Research output: Contribution to journal › Journal article › peer-review
Standard
Evaluation of registration methods on thoracic CT : the EMPIRE10 challenge. / Murphy, K.; van Ginneken, B.; Reinhardt, J.; Kabus, S.; Ding, K.; Deng, X.; Cao, K.; Du, K.; Christensen, G.; Garcia, V.; Vercauteren, T.; Ayache, N.; Commowick, O.; Malandain, G.; Glocker, B.; Paragios, N.; Navab, N.; Gorbunova, Vladlena; Sporring, Jon; de Bruijne, Marleen; Han, X.; Heinrich, M.; Schnabel, J.; Jenkinson, M.; Lorenz, C.; Modat, M.; McClelland, J.; Ourselin, S.; Muenzing, S.; Viergever, M.; De Nigris, D.; Collins, D.; Arbel, T.; Peroni, M.; Li, R.; Sharp, G.; Schmidt-Richberg, A.; Ehrhardt, J.; Werner, R.; Smeets, D.; Loeckx, D.; Song, G.; Tustison, N.; Avants, B.; Gee, J.; Staring, M.; Klein, S.; Stoel, B.; Urschler, M.; Werlberger, M.; Vandemeulebroucke, J.; Rit, S.; Sarrut, D.; Pluim, J.
In: IEEE Transactions on Medical Imaging, Vol. 30, No. 11, 2011, p. 1901-1920.Research output: Contribution to journal › Journal article › peer-review
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Evaluation of registration methods on thoracic CT
T2 - the EMPIRE10 challenge
AU - Murphy, K.
AU - van Ginneken, B.
AU - Reinhardt, J.
AU - Kabus, S.
AU - Ding, K.
AU - Deng, X.
AU - Cao, K.
AU - Du, K.
AU - Christensen, G.
AU - Garcia, V.
AU - Vercauteren, T.
AU - Ayache, N.
AU - Commowick, O.
AU - Malandain, G.
AU - Glocker, B.
AU - Paragios, N.
AU - Navab, N.
AU - Gorbunova, Vladlena
AU - Sporring, Jon
AU - de Bruijne, Marleen
AU - Han, X.
AU - Heinrich, M.
AU - Schnabel, J.
AU - Jenkinson, M.
AU - Lorenz, C.
AU - Modat, M.
AU - McClelland, J.
AU - Ourselin, S.
AU - Muenzing, S.
AU - Viergever, M.
AU - De Nigris, D.
AU - Collins, D.
AU - Arbel, T.
AU - Peroni, M.
AU - Li, R.
AU - Sharp, G.
AU - Schmidt-Richberg, A.
AU - Ehrhardt, J.
AU - Werner, R.
AU - Smeets, D.
AU - Loeckx, D.
AU - Song, G.
AU - Tustison, N.
AU - Avants, B.
AU - Gee, J.
AU - Staring, M.
AU - Klein, S.
AU - Stoel, B.
AU - Urschler, M.
AU - Werlberger, M.
AU - Vandemeulebroucke, J.
AU - Rit, S.
AU - Sarrut, D.
AU - Pluim, J.
PY - 2011
Y1 - 2011
N2 - EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra-patient thoracic CT image pairs. Evaluation of non-rigid registration techniques is a non trivial task. This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which comprised the comprehensive evaluation and comparison of 20 individual algorithms from leading academic and industrial research groups. All algorithms are applied to the same set of 30 thoracic CT pairs. Algorithm settings and parameters are chosen by researchers expert in the configuration of their own method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing. This article details the organisation of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed.
AB - EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra-patient thoracic CT image pairs. Evaluation of non-rigid registration techniques is a non trivial task. This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which comprised the comprehensive evaluation and comparison of 20 individual algorithms from leading academic and industrial research groups. All algorithms are applied to the same set of 30 thoracic CT pairs. Algorithm settings and parameters are chosen by researchers expert in the configuration of their own method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing. This article details the organisation of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed.
U2 - 10.1109/TMI.2011.2158349
DO - 10.1109/TMI.2011.2158349
M3 - Journal article
VL - 30
SP - 1901
EP - 1920
JO - I E E E Transactions on Medical Imaging
JF - I E E E Transactions on Medical Imaging
SN - 0278-0062
IS - 11
ER -
ID: 33950080